OEM Pressure Measurement Cells

Pressure Measurement Cells OEMFor further assembly, the OEM measurement cells could be welded onto adaptors and are completed with color-coded litz-wires. In the standard program, G1/4-threads parts are offered; however, customer-specific solutions can be realized quickly by changing the adaptors. The OEM measurement cells covers a temperature range of -40…+200°C / (-40…+392°F).

Datasheet

OEM Pressure Measurement Cells

Specifications

System Data
Pressure range 25 bar to 3000 bar
Hysteresis <0.1 % FS (typ.)
TC zero offset <0.02% FS/K (typ.)
TC measurement span <0.01% FS/K (typ.)
Linearity deviation <0.2% FS (typ.) at 60 bar to 3000 bar, <0.5% FS (typ.) up to 25 bar
Environmental Requirements
Application range Process engineering, industry and research, test stands, hydraulics systems