OPTI Pressure Measurement Cells

Pressure Measurement Cells OPTI

In the news : STW to Exhibit at Sensors Expo 2017 Booth 1236

This stainless steel sensor is typically welded onto a stainless steel adaptor. The electrical connection is realized via bonding. The sensor can also be delivered pre-welded onto an adaptor. The OPTI measurement cell covers a temperature range of -40…+200°C /  (-40…+392°F).

Datasheet

OPTI Pressure Measurement Cells

Specifications

System Data
Pressure range 50 bar to 2000 bar
Hysteresis <0.2% FS
TC zero offset <0.15% FS/K
TC measurement span <0.05% FS/K
Linearity deviation <0.5% FS
Environmental Requirements
Application range Test stands, hydraulic systems